Welcome to our Mining equipment manufacturing base, Contact Us


Pile load testing is the most definitive method of determining load capacity of a pile. Testing a pile for failure provides valuable information to the design engineer and is recommended for load tests performed prior to the foundation design. We at Struct Geotech follow IS: 2911 (Part 4) – 1985, IS: 14893-2001 load test on piles method. This ...


load/settlement performance of the tested pile. Dynamic load testing of cast in place piles is used to predict the static soil resistance and the load/settlement behavior. The test method is similar to that used on driven piles with the monitoring of hammer blows and subsequently analyzing the pile response to the stress wave propagation. A ...


Of the 15 test piles, only one pile (IPW) was loaded to failure in a static load test. Likewise, only four BOR CAPWAP analyses and eight EOD CAPWAP analyses mobilized the full soil resistance. This means that the true ultimate capacity of the majority of the piles tested was not reached, and this makes a comparison of static load test and ...


Street Light Pole Foundation Construction Method Statement. The purpose of this method statement is to describe the procedure and activities involved in the construction of Street light pole foundations in the project complying all contract requirements. All quality control procedures to be implemented in systematic way, works shall be.


Dynamic Load Testing is a fast, reliable and cost effective method of evaluating foundation bearing capacity. GRL can perform Dynamic Load Testing on driven piles, drilled shafts, auger-cast piles, micropiles, helical piles, and other cast in place foundations. It is often possible to conduct several dynamic load tests in a single day.


Rotations at the tops of single piles depend on the magnitude of the applied load and the pile-head restraining condition. The maximum slope measured at the groundline during load testing was slightly less than 3 degrees for the north pile in dense sand. This occurred at a 45 kip load and a deflection of approximately 3.5 inches; a situation


The static and the dynamic pile testing methods are the two main types of pile tests that are. periodically used to assess the pile load capacity. The static pile load test is conducted at low ...


4. Cleaning Bucket. 5. Rock Reamer. 6. many tests methods have been used over the years to test the pile In Tension Pile method a reaction frame is constructed around the test pile the frame is anchored to reaction (Tension) piles pile is incrementally loaded with an hydraulic jack. 7. the test load is measured by a Load Gauge deformation is ...


Being a market leader of this domain, we provide clients with Piling Services (By DMC Augor Method ) Soil Testing pile Load Testing Land Building Survey . Known for systematic DMC piling, the rendered services of DMC piling can be custom designed. The DMC piling services are known for their execution within promised time frame. For attaining maximum client approval, the DMC Piling Services are ...


Plate Load Test. Plate Load Test is a field test for determining the ultimate bearing capacity of soil and the likely settlement under a given load. The Plate Load Test basically consists of loading a steel plate placed at the foundation level and recording the settlements corresponding to each load increment. The test load is gradually increased till the plate starts to sink at a rapid rate.


This paper discuss the results of three dynamic and static load test on cast-in-situ bored pile of length to diameter ratio 28, 25.5 and 23.47. The load-settlement response of dynamic and static ...


Jacking against reaction piles is the most economical method, with the load in these piles limited to 25 to 50 percent of the test pile's load. Reaction piles must be located a minimum of five feet from the tested pile, with provisions made to detect any upward movement. For modest loads, wood reaction piles cabled together, with a test beam ...


Get More Information

Supercell-India

The new best way for testing pile load, improved method of static load tests and foundation load tests! Bi-directional load test (or otherwise named Osterberg test or O-cell test) utilizes the hydraulically operated 'Super Cell' load cells, embedded within the concrete of the pile shaft for load and pile capacity testing.


Doc. Title Method Statement for Static and PDA Load Test of pile for Building TOA-TOYO JOINT VENTURE Doc. No CM – MS – BW - 003 Rev. No. 0 Date July, 2010 C…


Point Load Test As a piling contractor, we also provide various type of pile testing in order to justify the design and quality of pile after installation. For Bored Pile, we offer testing of load test with test load up to 7000 ton using Conventional Kentledge Method, Bi-Directional Method or Statnamic Method.


This test can be performed either on a working pile that forms the foundation of the structure or on a test pile. Pile loading test is one of the most common methods for testing the actual in-situ load capacity of any pile. The test method involves the direct measurement of pile head displacement in response to a physically applied load.


Fig: Horizontal load test on piles. The jack should be placed horizontally, between two piles. The load on the jack shall be the same on both the piles. The load will be applied in increments of 20% of the estimated safe load and at the cut off level. The load will be increased after the rate of displacement is nearer to 0.1 mm per 30 minutes.


ASTM D4945‐08 Standard Test Method for High Strain Dynamic Testing of Piles. It may be performed on driven piles, drilled piles and other cast in place foundations. In addition to bearing capacity, Dynamic Load Testing gives


Get More Information

STATIC PILE LOAD TEST MANUAL

support pile diameters and 5 test pile diameters (whichever of the two criteria is the greater distance) from the test pile or reference beam supports. For drilled shafts or micropiles, locate these support piles not less than 10 ft. (3 m) or 5 reaction pile diameters (whichever of the two criteria is the greater distance) from the test pile or


3.15 Routine Test Pile — A pile which is selected for load testing may form a working pile itself, if subjected to routine load test up to 1.5 times the safe load. 3.16 Safe Load — It is the load derived by applying a factor of safety on the ultimate load capacity of the pile or as determined from load test. 3.17 Ultimate Load Capacity ...


Vertical compression load test (static load test) using the Kentledge Method The Kentledge method involves the construction of a platform upon which weights are placed. These weights bear down on the piles putting it under load, the gauges then measure resistance, movement of the pile and other readings to determine the design load of the piles.


Method statement of bored piles is a construction procedure which includes hole boring into the ground, installing steel reinforcement and casting with concrete to form a pile, etc. Bored piles are constructed in the ground by boring in the circular shape of designed diameters to transfer load from the superstructure into the ground through friction and end bearing.


L-Pile calibration 50% Fixity SCHNABEL ENGINEERING Length : 39 ft Date Installed : 7/11/2002 Date Tested : 7/16/2002 ASSOCIATES Remarks: Lateral Load Test - TP-1 0.43" Thick Wall 80 ksi Steel 4000 psi Grout 2 - 15 ft. long #18 75 ksi Williamsform Bars Design Load : 10 Kips Test Load : 20 Kips CONTRACT NO. DATE Pile Type : 7-5/8" O.D. Micropile ...


Test procedure, method statement template. 1. SCOPE. This test method covers the procedure for High Strain Dynamic testing of Piles to determine the force and velocity response of the pile to an impact force applied axially by a pile driving hammer that will cause a large strain impact to the top of the pile. 2.


of penetration test method. •THE PURPOSE of pile load testing can be either to prove the adequacy of the pile-soil system for the proposed pile design load or to develop criteria to be used for the design and installation of the pile foundation. Tests in the first category are generally routine,


METHOD STATEMENT FOR ANTI TERMITE. 1. Scope of Work. a) Main contractor shall notify pest control operator 24 hours in advance that anticipates concrete casting into the area to be treated. b) Before area treated, Main Contractor shall ensure that all loose timber, wood shaving, loose containing materials be removed from the said allocation area.


8-2.1 Static Pile Load Tests. The static pile load test gives the most accurate indication of the capacity of the in-place pile. It is performed using a reaction method. The test procedure involves applying an axial load to the top of the test pile with one or more hydraulic jacks.


the test pile performance to be monitored throughout the full duration of the test. 2.3 Load application limits The maximum test load to be applied must be agreed in advance so that the test pile, pile cap (if required) and the load testing equipment (reaction piles/kentledge/


the interpretation of test results are also given. NOTE - In view of the limitations of each method of non-destructive testing of concrete, it is essen!ial that the results .of tests obtained by one method should be complimented by other tests and each method should be aqopted very carefully. 2 OBJECT


The plate load test is a field test, which is performed to determine the ultimate bearing capacity of the soil and the probable settlement under a given load. This test is very popular for the selection and design of the shallow foundation. For performing this test, the plate is placed at the desired depth, then the load is applied gradually ...


The object of this Method Statement is to conduct High Strain Dynamic Pile Load Test on Bored cast in-situ piles to verify the safe load capacity of pile. 2. References: 2.1 ASTM D 4945 – 12 "Standard Test Method for High-Strain Dynamic Testing of Deep Foundations"